DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-24099

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Night (22:00–06:00) · 363 of 395 min running
72%

Availability

92.0%

Performance

79.5%

Quality

98.7%

Current job
WO-24114
Bracket, actuator · AD-3310-A

Pieces

31 / 40

Cycle time

4m 56s

This piece

1m 10s elapsed

Operator

Arden Adams

Tool

T22 · Ø20 shell mill

Tool life left

43%

Finishes

17 Oct 05:17

Losses
Downtime by reason
31.5 minutes lost this shift, biggest first.

Setup / first-off

13.2 min

Tool change

6.6 min

No material

4.1 min

Waiting QA

3.5 min

No operator

2.1 min

Breakdown

2.1 min

Quality
Pieces this shift
Ideal 228 s versus actual 287 s per piece.

Good

74

Scrap

1

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24114

High

Helvetica Medtech · AD-3310-A OP10 · Al 7075-T6 · setup 112 min

Late

31/40 · due 17 Oct 00:34

WO-24115

Aerodyn Systems · NT-6650-A OP20 · Inconel 718 · setup 55 min

Queued

0/40 · due 18 Oct 19:34

WO-24116

Sandvik Tooling · ST-3390-A OP30 · H13 tool steel · setup 96 min

Queued

0/24 · due 19 Oct 14:34

Readings
Live telemetry
Polled every 5 seconds · spindle 18,506 h, service in 343 h

Spindle load

70 %

Spindle speed

8,547 rpm

Feed rate

1,726 mm/min

Spindle temp

48.3 °C

Coolant temp

27.1 °C

Coolant pressure

17.9 bar

Vibration

1.84 mm/s

Axis load B

31 %

Axis positions

X

-129.2

Y

67.1

Z

-62.2

B

-37.5

C

262.1

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 10-17 03:14

high

B axis drive temperature high

Alarm 1105 · 10-17 02:24

medium

Tool life expired on T7, change required

Alarm 2019 · 10-17 02:02

low

B axis drive temperature high

Alarm 1105 · 10-16 08:33

medium

Tool life expired on T7, change required

Alarm 2019 · 10-16 02:27

high

Coolant level low in the tank

Alarm 7014 · 10-15 12:52

high

Coolant level low in the tank

Alarm 7014 · 10-15 12:05

high

Coolant level low in the tank

Alarm 7014 · 10-15 08:10

high