DMU-09

DMG MORI DMU 50 (3rd Generation) · Heidenhain TNC 640 · Bay 3 · Cell A · s/n DMU50-22970

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Night (22:00–06:00) · 364 of 385 min running
80%

Availability

94.5%

Performance

85.2%

Quality

100.0%

Current job
WO-24152
Blade root fixture · NT-6650-A

Pieces

24 / 24

Cycle time

5m 40s

This piece

1m 06s elapsed

Operator

Arden Adams

Tool

T5 · Ø8 ball nose

Tool life left

69%

Finishes

—

Losses
Downtime by reason
21.4 minutes lost this shift, biggest first.

Setup / first-off

7.5 min

Tool change

5.4 min

No material

3.5 min

Waiting QA

2.3 min

No operator

1.4 min

Breakdown

1.2 min

Quality
Pieces this shift
Ideal 276 s versus actual 324 s per piece.

Good

67

Scrap

0

Rework

0

OEE per hour · %

Queue
Jobs on this machine (4)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24152

Brunner Hydraulik · NT-6650-A OP20 · Inconel 718 · setup 102 min

Running

24/24 · due 17 Oct 19:25

WO-24153

Vogt Optics · AD-3310-A OP30 · Al 7075-T6 · setup 71 min

Queued

0/40 · due 18 Oct 06:25

WO-24156

Brunner Hydraulik · BH-9021-D OP10 · Al 6082 · setup 89 min

Queued

0/24 · due 19 Oct 00:25

WO-24160

Nordwind Turbinen · VO-2075-A OP10 · Invar 36 · setup 74 min

Queued

0/40 · due 21 Oct 00:25

Readings
Live telemetry
Polled every 5 seconds · spindle 15,276 h, service in 658 h

Spindle load

71 %

Spindle speed

9,011 rpm

Feed rate

1,718 mm/min

Spindle temp

48.4 °C

Coolant temp

26.8 °C

Coolant pressure

17.7 bar

Vibration

1.9 mm/s

Axis load B

29 %

Axis positions

X

-178.8

Y

-21.6

Z

-83.9

B

-52.1

C

80.6

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

C axis following error

Alarm 1188 · 10-17 01:53

low

Spindle lubrication cycle overdue

Alarm 2214 · 10-17 00:24

high

Tool life expired on T7, change required

Alarm 2019 · 10-16 19:40

high

Probe measurement out of tolerance

Alarm 5502 · 10-16 10:46

medium

Coolant level low in the tank

Alarm 7014 · 10-16 08:56

high

Chip conveyor jammed

Alarm 3320 · 10-15 15:03

medium

Tool life expired on T7, change required

Alarm 2019 · 10-15 05:11

medium

Coolant level low in the tank

Alarm 7014 · 10-15 04:28

medium